Skip to content
LCALens

Guides · Scope 2: electricity and heat

UK electricity emission factor (DESNZ 2026): what each number covers

The four UK government electricity factors for 2026, generation, grid losses and their upstream emissions, which scope each belongs to, and how they add up per kWh.

By LCALens. Published 8 Oct 2026, 2 min read.

Part of Scope 2 emissions from electricity and heat: how to calculate them.

The UK government's conversion factors, published each year by the Department for Energy Security and Net Zero (DESNZ), are the standard source for UK grid electricity. For 2026 there is not one electricity factor but four, and each belongs to a different part of the inventory. See Scope 2 emissions for the overall method.

The four factors

kg CO2e per kWh of electricity you consume, DESNZ 2026:

FactorWhat it coversScopeValue
Electricity generatedEmissions at UK power stationsScope 2 (location-based)0.13096
Transmission and distributionGeneration emissions of the electricity lost in the gridScope 3, category 30.01299
WTT, generationProducing and delivering the fuels used by power stationsScope 3, category 30.03682
WTT, T&DUpstream fuel emissions for the electricity lostScope 3, category 30.00359
All four0.18436

All four are applied to the same number: the kWh on your bills. Only the first goes into Scope 2.

Why they are separate

The GHG Protocol keeps generation in Scope 2 and puts losses and upstream fuel emissions in Scope 3 category 3, whose activities include "Transmission and distribution (T&D) losses" and the upstream emissions of purchased electricity. Splitting them prevents double counting between companies: the generator reports combustion as its Scope 1, you report it as Scope 2, and the upstream parts are value-chain emissions for both.

Worked example

An office uses 120,000 kWh in a year:

FactorCalculationEmissions
Generation (Scope 2)120,000 × 0.1309615,715 kg
T&D losses (category 3)120,000 × 0.012991,559 kg
WTT generation (category 3)120,000 × 0.036824,418 kg
WTT T&D (category 3)120,000 × 0.00359431 kg
Total120,000 × 0.1843622,123 kg

Reporting only Scope 2 would show 15.7 tonnes; the full chain is 22.1 tonnes, about 41% more.

Use the factor for the right year

DESNZ updates the factors every year as the generation mix changes. Use the set published for your reporting year, and do not mix years within one inventory.

Market-based

The DESNZ generation factor is a location-based grid average. If you buy electricity on a renewable tariff backed by certificates, you report a separate market-based figure; see location-based vs market-based Scope 2.

Calculate it

More on Scope 2: electricity and heat

Sources

  1. UK Government GHG Conversion Factors for Company Reporting 2026, Department for Energy Security and Net Zero (accessed 2026-10-08)
  2. Technical Guidance for Calculating Scope 3 Emissions, Chapter 3: Category 3, World Resources Institute / WBCSD (accessed 2026-10-08)
  3. GHG Protocol Scope 2 Guidance, Executive Summary, World Resources Institute / WBCSD (2015) (accessed 2026-10-08)

This guide explains methods and published data. It is not legal or assurance advice. LCALens is designed to align with the GHG Protocol and ISO 14064-1 but is not certified or endorsed by either body.